← Về thư mục
📄 / / profiles / r-and-d / raw_evidence / scientific-agent-skills / skills / uncertainty-and-units / references / plausibility-scales.md

Plausibility: dimensionless groups, characteristic scales, and magnitude bands

Dimensional analysis proves a calculation is consistent. It cannot prove the answer is possible. A cell 2 m across, a Reynolds number of 4×10⁷ in a capillary, and a diffusion time of 300 years across a lipid bilayer are all dimensionally impeccable, and a unit-checking library will pass every one of them.

The three checks below close that gap. scripts/check_plausibility.py runs all of them and verifies dimensional consistency of each formula before reporting a number.


1. Choose the characteristic length first

The single most common error in this whole area is not an arithmetic slip — it is using the wrong length. The dimensionless groups are only meaningful with the length the correlation was fitted against.

Geometry Characteristic length
Flow in a circular pipe inside diameter, not radius
Flow in a non-circular duct hydraulic diameter 4A/P
External flow over a plate distance from the leading edge
Flow past a sphere or cylinder diameter
Conduction in an irregular body (Biot) volume / surface area
Packed bed particle diameter
Open channel hydraulic radius A/P — note: radius, not diameter

Using radius where the correlation wants diameter puts every threshold out by a factor of two, which is exactly the size of error that survives review.

2. Dimensionless groups and what they gate

Each threshold is a modelling decision boundary: past it, an assumption in your analysis stops holding.

Group Definition Threshold What stops being true past it
Reynolds Re ρvL/μ 2300 / 4000 (pipe) laminar solutions; above 4000 you need a turbulence model
Péclet Pe vL/D ≈ 1 below 1 diffusion dominates, so stirring will not help
Damköhler Da_I kL/v 0.1 / 10 above 10 the reagent is consumed at the inlet, so the reactor is transport-limited
Knudsen Kn λ/L 0.01 the no-slip boundary condition, then the continuum assumption itself
Mach Ma v/c 0.3 incompressibility, at about 5% density change
Womersley Wo R√(ωρ/μ) 1 / 10 the parabolic (Poiseuille) profile; above 10 the core moves as a plug
Capillary Ca μv/σ ≈ 10⁻³ an interface whose shape is set by surface tension alone
Weber We ρv²L/σ ≈ 12 drop integrity — above it, aerodynamic breakup
Bond Bo Δρ g L²/σ 1 surface tension holding a drop against gravity
Stokes Stk ρ_p d² v / (18 μ L) 0.1 the tracer assumption behind PIV and aerosol sampling
Biot Bi hL/k 0.1 lumped-capacitance (uniform internal temperature)
Fourier Fo αt/L² 0.05 / 1 the semi-infinite solution; above 1 the body has equilibrated
Schmidt Sc μ/(ρD) — ≈ 1 for gases, ≈ 10³ for small molecules in water
Deborah De t_relax/t_obs 1 whether the material is a liquid or a solid on your timescale

Womersley takes angular frequency. Pass 2πf, not f. A resting human heart at 1.2 Hz gives ω ≈ 7.5 rad/s, and in the aorta Wo ≈ 20 — firmly plug-like, which is why Poiseuille's law is the wrong model for arterial flow and the right one for a capillary.

The Reynolds thresholds are pipe-flow values. Transition over a flat plate is around Re ≈ 5×10⁵; for flow past a sphere the wake becomes unsteady near Re ≈ 100. The tool reports the pipe classification and says so.

3. Characteristic scales

Scale Formula Sanity anchor
Diffusion time L²/D 10 µm at 10⁻⁹ m²/s → 0.1 s
Thermal diffusion time L²/α same form, thermal diffusivity
Thermal energy k_B T 4.14×10⁻²¹ J at 300 K
Molar thermal energy RT 2.49 kJ/mol at 300 K
Stokes settling velocity Δρ g d²/(18μ) 1 µm bead in water → ≈ 0.5 µm/s
Mean free path (gas) k_BT/(√2 π d² p) air at 1 atm → ≈ 68 nm
Debye length √(ε₀ε_r k_B T / (2 N_A e² I)) 100 mM → 0.96 nm
Capillary length √(σ/(ρg)) water → 2.7 mm

The L² in diffusion time is the whole story of cell biology. Ten micrometres takes 0.1 s; one millimetre takes 1000 s; one centimetre takes 10⁵ s ≈ 28 hours. This is why cells are small, why tissue thicker than ~200 µm needs a blood supply, and why a claim that a molecule "diffuses across the tissue in seconds" is worth checking.

Stokes settling is valid only while the particle Reynolds number stays below ≈ 0.1. Compute the settling velocity, then feed it back into the reynolds group with the particle diameter as the length. If Re_p > 0.1, the drag law is wrong and the velocity is an overestimate.

4. Magnitude bands

These are deliberately generous observed ranges. A value outside one is worth a second look, not automatically wrong — the tool reports questionable inside one decade and implausible beyond it.

Band Range Source
Bacterial cell diameter 0.2–10 µm Milo & Phillips, Cell Biology by the Numbers, ch. 1
Eukaryotic cell diameter 5–100 µm Milo & Phillips, ch. 1
Cell membrane thickness 3–5 nm Alberts et al., MBoC 7th ed., ch. 10
DNA base-pair rise 0.32–0.36 nm Bloomfield et al., Nucleic Acids
Ribosome diameter 20–30 nm Milo & Phillips, ch. 1
Protein molar mass 5–1000 kDa Milo & Phillips, ch. 1
Human capillary diameter 5–10 µm Guyton & Hall, 14th ed., ch. 16
Mammalian body temperature 306–315 K Guyton & Hall, ch. 74
Resting heart rate 0.7–3 Hz Guyton & Hall, ch. 9
Blood plasma osmolarity 275–300 mol/m³ Guyton & Hall, ch. 25
Small-molecule diffusivity in water 3×10⁻¹⁰–3×10⁻⁹ m²/s Cussler, Diffusion 3rd ed., app. A
Protein diffusivity in water 10⁻¹¹–1.5×10⁻¹⁰ m²/s Cussler, app. A
Dynamic viscosity of water 0.5–1.5 mPa·s IAPWS R12-08
Surface tension of water 0.06–0.08 N/m IAPWS R1-76
Speed of sound in water 1400–1560 m/s Del Grosso & Mader, JASA 52:1442 (1972)
Speed of sound in air 320–350 m/s Cramer, JASA 93:2510 (1993)
Sea-level atmospheric pressure 95–105 kPa ISO 2533
Earth surface gravity 9.76–9.84 m/s² WGS 84 normal gravity
Visible wavelength 380–750 nm CIE S 017:2020
Non-covalent bond energy 1–40 kJ/mol Israelachvili 3rd ed., ch. 2
Covalent bond energy 150–1000 kJ/mol Atkins & de Paula 12th ed.
ATP hydrolysis free energy 40–60 kJ/mol Milo & Phillips, ch. 4

Compare binding energies against RT, not against zero. At 300 K, RT is 2.5 kJ/mol. A reported binding free energy of 1 kJ/mol is not a weak interaction; it is indistinguishable from thermal noise.

5. The three errors this catches

A quantity of the wrong kind. Kinematic viscosity (m²/s) where the formula needs dynamic (Pa·s) is the classic. Both are called "viscosity", both are tabulated for water, and they differ by a factor of ρ ≈ 1000. The dimensionality check refuses it before any number is computed:

error: viscosity must have dimensionality [mass] / ([length] * [time]),
       but m²/s is [length] ** 2 / [time]

A unit prefix slip. Micro for milli is three decades. The magnitude bands catch it whenever the quantity is one the table knows.

An assumption used outside its regime. Applying Poiseuille's law at Wo = 20, the lumped-capacitance model at Bi = 5, or Stokes drag at Re_p = 30 all produce a number. The group tells you the number is meaningless.

6. Caveats

Sources

Checked 2026-07-26: