Pharmacodynamics and exposure-response

Direct effect models

Linear          E = E0 + S*C
Log-linear      E = E0 + S*ln(C)                 no plateau; only valid over a narrow range
Emax            E = E0 + Emax*C/(EC50 + C)
Sigmoid Emax    E = E0 + Emax*C^h/(EC50^h + C^h)
Inhibitory      E = E0 * (1 - Imax*C^h/(IC50^h + C^h))

The Hill coefficient h controls steepness. h = 1 is simple hyperbolic binding; h > 1 implies cooperativity or an amplification step; h between 2 and 4 is common for a downstream clinical endpoint even when the receptor binding itself is 1:1.

The single most important diagnostic is how far up the curve the data reach. If the highest observed exposure produces less than half of the estimated Emax:

exposure_response.py --emax reports fraction_of_emax_reached and raises a finding below 0.5. When you are in this regime, report the slope, not Emax and EC50.

Imax is bounded by 1 for a model that can achieve complete inhibition; estimating Imax > 1 means the model is being used outside its structure.

Indirect response models (Dayneka & Jusko)

Response R has its own turnover: production kin, first-order loss kout, baseline R0 = kin/kout. The drug perturbs one of the two.

Type Equation Drug acts on Example
I dR/dt = kin*(1 - I) - kout*R Inhibits production Statins on cholesterol synthesis
II dR/dt = kin - kout*(1 - I)*R Inhibits loss Diuretic effects on sodium
III dR/dt = kin*(1 + S) - kout*R Stimulates production Erythropoietin on reticulocytes
IV dR/dt = kin - kout*(1 + S)*R Stimulates loss

where I = Imax*C^h/(IC50^h + C^h) and S = Emax*C^h/(EC50^h + C^h).

Key properties that distinguish IDR from a direct model with an effect compartment:

dCe/dt = ke0 * (C - Ce),      E = f(Ce)

A hypothetical compartment with no mass that collapses counter-clockwise hysteresis. ke0 sets the equilibration half-life, ln(2)/ke0. Use it when the hysteresis is a distribution delay (anaesthetics, neuromuscular blockers). Use IDR when the delay is turnover of the measured response.

_models.effect_compartment() solves each interval exactly under a linear interpolation of plasma concentration, so the result does not depend on grid density; the usual explicit-Euler implementation understates Ce peaks on sparse grids.

Tolerance and rebound

If the response drifts back towards baseline during constant exposure, no direct or simple IDR model will fit, and adding compartments to the PK will not help.

Disease progression

For a chronic endpoint the placebo/natural-history trajectory must be modelled, or the drug effect absorbs it:

Linear progression      S(t) = S0 + alpha*t
Asymptotic              S(t) = S_ss + (S0 - S_ss)*exp(-k*t)

with the drug entering as symptomatic (an offset that disappears on withdrawal) or disease-modifying (a change in alpha that persists). Distinguishing these requires a randomised-withdrawal or delayed-start design; no amount of modelling of a parallel-group trial will separate them.

Exposure-response analysis for dose selection

The three metrics, and when each is the right one:

Metric Right for
AUC or Cavg Effects driven by total exposure over time
Cmax Concentration-driven toxicity; some cardiovascular effects
Cmin / Ctrough Effects requiring continuous target coverage; antivirals, antibiotics

Choose on mechanism before fitting, not by comparing fits. The three are highly correlated within a single regimen, so the data will rarely discriminate; different regimens (same daily dose, different interval) are what separate them.

The confounding problem. Patients are randomised to dose, not to exposure. Within a dose group, exposure varies because of clearance, and clearance varies with the same factors that drive outcome — renal function, hepatic function, albumin, body size, inflammatory status, disease severity. In oncology this produces a well-documented artefact: an apparent efficacy benefit of higher exposure that is partly a marker of better baseline health. Mitigations: include the confounders as covariates in the E-R model, use case-matching, or compare across randomised dose groups rather than across exposure quantiles.

Safety and efficacy E-R must both be modelled. A dose optimal for efficacy alone is not optimal. FDA's Project Optimus dose-optimisation guidance (final, August 2024) makes this explicit for oncology: identify a dosage that maximises benefit-risk rather than the maximum tolerated dose, support it with PK/PD and exposure-response, and use randomised comparison of more than one dosage. The PK sampling and analysis plan should be in each protocol and sufficient to support population PK and dose/exposure-response analyses.

Concentration-QTc

The framework in ICH E14 and its Q&A documents, and ICH S7B:

Check the model assumption of linearity and of a zero intercept: a non-zero intercept suggests the placebo correction or the baseline is wrong, and a nonlinear concentration-effect relationship invalidates the extrapolation to supratherapeutic exposure.