Adapter Trimming - Usage Guide

Overview

Sequencing adapters appear in reads only when the insert is shorter than the read length (read-through), so adapter content is a direct readout of the insert-size distribution. Adapter is foreign sequence with genuine base quality, so aligners may mis-anchor on it -- which is why adapter trimming is the one near-universal preprocessing step (quality trimming usually is not, because aligners soft-clip). Cutadapt gives precise, error-tolerant control; Trimmomatic adds palindrome mode for paired read-through; fastp trims paired adapters from the read overlap with no adapter sequence needed.

Prerequisites

# Cutadapt
conda install -c bioconda cutadapt
# Trimmomatic
conda install -c bioconda trimmomatic
# fastp (all-in-one alternative)
conda install -c bioconda fastp

Quick Start

Tell your AI agent what you want to do: - "Remove TruSeq adapters from my paired-end reads" - "Trim small-RNA adapters and keep only 18-30 nt inserts" - "My FastQC adapter-content curve climbs toward the 3' end, fix it" - "Remove amplicon primers from my reads"

Example Prompts

Standard trimming

"Remove TruSeq adapters from my paired-end FASTQ files and discard reads shorter than 20 bp"

"Trim Nextera adapters from my reads with Cutadapt"

Short-insert / small-RNA

"Trim the small-RNA 3' adapter, gate inserts to 18-30 nt, and drop reads with no adapter"

"My inserts are short (cfDNA) so most reads read through; trim the adapter from both mates"

Read-through and troubleshooting

"Detect paired read-through without knowing the adapter sequence"

"FastQC still shows adapter after trimming, raise the error tolerance and use the shared stem"

What the Agent Will Do

  1. Identify the adapter from the kit, FastQC overrepresented sequences, or read-through detection
  2. Choose the tool (cutadapt for precision/small-RNA/amplicon, fastp for bulk PE overlap, Trimmomatic for palindrome)
  3. Trim 3' adapter from both mates together, keeping pairs synchronized
  4. Apply a minimum-length filter so adapter dimers (which collapse to ~0 bp) are dropped
  5. Verify removal with post-trim FastQC

Common Adapter Sequences

Library Adapter
Illumina TruSeq (shared stem) AGATCGGAAGAGC
Nextera / Tn5 CTGTCTCTTATACACATCT
Small RNA TGGAATTCTCGGGTGCCAAGG

Tips

Resources

read-qc/quality-reports - Read the adapter-content panel that triggers trimming read-qc/quality-filtering - Quality and length filtering after adapter removal read-qc/fastp-workflow - All-in-one adapter + quality trim with auto poly-G read-qc/contamination-screening - k-mer removal of PhiX/vector/contaminant sequence small-rna-seq/smrna-preprocessing - Full small-RNA adapter + length workflow